From: John De Armond Newsgroups: rec.outdoors.rv-travel Subject: Re: Inverter/Charger Question Message-ID: <7uflhu07bba23mptt9odr8u1ie7bhquslh@4ax.com> Date: Thu, 27 Jun 2002 12:53:55 -0400 On Thu, 27 Jun 2002 05:10:10 GMT, Owlman <owlman@cox.net> wrote: >I recently posted a message requesting information re inverter/charger >systems. I was told my many that if I wanted to be able to power our >microwave/convection oven that I would have to get a true sine wave >inverter. My RV servicer (in whom I've always had extreme trust) ended >up installing a Heart modified sine wave unit in my RV. Since I thought >we'd discussed the need for a true sine wave unit, I was shocked to find >it wasn't. When I contacted him today, he said that he'd never heard of >any problems with this unit powering a microwave and that he's installed >numerous such units for exactly that use. I felt a little relieved, but >based on comments from this newsgroup, I'm also still a little nervous. >I read through the instructions for my inverter and the only thing they >said was that there could be problems with "some" battery chargers and >digital clocks. Of course, the microwave/convection has a digital clock >and we haven't seen a problem yet. If you got advice in this forum that a microwave has to have a true sine wave inverter in order to work, the advice-giver doesn't have a clue. Here is the issue. Internally, the oven has a transformer that steps line voltage up to about 2000 volts, plus or minus. In a clever circuit that uses the magnetron as both the source of microwaves and a diode, this voltage is rectified and doubled to produce the necessary ~3500-4000 volts that it takes to operate the magnetron. As with any conventional rectifier circuit and particularly with a voltage doubler, the DC voltage produced (and thus the microwave power developed) is proportional to the PEAK value of the AC voltage. The utility supplied power is more or less a sine wave so the peak value is a known and is used in the design. Making a sine wave is fairly expensive in an inverter circuit so simpler methods have been developed. For resistive and some inductive (motor) loads, the inverter can simply toggle the polarity of the 120 volt output 120 times a second. This produces a 60 hz square wave. the problem is that the peak and average value is the same and so there is insufficient peak voltage to make the microwave work. A microwave plugged into a square wave inverter will power up, the controls, lights and fan will work but it won't make any power. The solution is to modify the switching. One method involves switching several different voltages in sequence so that the output is a stair step that roughly resembles a sine wave. As long as the peak voltage is there, the microwave will be perfectly happy and could care less what the actual shape is. Another method, common with most inexpensive inverters I've analyzed, is to add some delay between the time when one polarity is turned off and the other is turned on. If the timing is chosen correctly, the resultant waveform will have both the same RMS and peak voltage as the utility power, though it won't look like a sine wave. The microwave will also operate happily on this waveform. The only difference will be that if the oven has a noisy transformer and hums, the hum will have a sharper edge to it. Last year I wrote a nice paper on this topic complete with waveform pictures and posted it to my web site. It's probably still there if you want to look. > >I know that some folks commented that they had no problem using a >modified wave for a microwave, I'm still concerned of what such a unit >might due long-term to the microwave. I guess we'll have our first >trial over July 4th weekend. There is no long term effect. Don't know where those urban legends get started. Either the oven heats satisfactorily on the inverter or it doesn't. John From: John De Armond Newsgroups: rec.outdoors.rv-travel Subject: Re: RV input power measurements Message-ID: <l2kgjv85iiaogjd2a1v32pn7om4mahocm2@4ax.com> Date: Mon, 11 Aug 2003 22:42:56 -0400 On 10 Aug 2003 12:02:57 -0700, jafo2000@my-deja.com (Jim) wrote: >Recently saw that BJ's club was selling Superex 1000w inverters for >$70. Thought I might be able to use this for the microwave in the RV >so I went and took some measurements. With the microwave operating I >was measuring 1065-1090w, 10.8 amps at 105.5 volts (on the input to >the RV). With the microwave off I measured 71 watts, 3.0 amps and >120v. > > From this I've determined that the Superex 1Kw inverter would be >questionable to run the microwave with.. even though it's rated for >2Kw surge, I haven't seen any charts that show how long a 'surge' is.. >anyone have any thoughts on this?.. BJ's has a 2500w Superex inverter, >but they are asking $299. I run a nominal 600 watt microwave just fine on a 1kw Vector inverter. I haven't yet measured the line draw but I'd expect it to be somewhere in that range. The only way to know for sure about that combo is to try it. It may very well work. These pseudo-sine (stepped square wave) inverters tend to not deliver the peak voltage of a pure sine wave. That reduces the power output and thus the draw significantly. I haven't measured my microwave yet but subjectively, I know that it doesn't produce as much power on the inverter as it does on line power. I did a very detailed test on the Vector unit some months back for someone in this group (sorry, bad on names.) It will carry its rated load indefinitely but will shut down on a time vs overload curve when one goes beyond the rating. The surge rating really is what it says - only for a few seconds. One thing I did observe on the Vector was that the high voltage filter capacitors get very hot at full load, much hotter than is conducive to long life. Since it appears that most of these cheap chinese made inverters use the same circuitry, I'd not be surprised to see that on yours. yet another reason not to try to run it at full load for long. In mine I arranged a little fan to blow directly on the capacitors. That and the built-in chassis fan seems to do a pretty good job. Rather than have to wonder I think I'd grab the 2.5kw inverter. that's a nice price. > The other question is that something running in the RV has a horrible >power factor.. 71 watts and 3.0 amps?.. could this be the battery >charger? Probably the converter. You definitely don't want to be running the converter from your inverter. That's purely wasted power. The way I wired my unit is thus. My reefer and microwave sit adjacent to each other and are powered off the same branch which runs through the back of the refrigeration compartment. I installed a DPDT relay in the compartment. The moveable contacts go to the two outlets. The NC contacts go to the existing shore power branch and the NO contacts go to the inverter. The 120 VAC coil is also connected to the inverter. Operation is thus. On AC the relay is de-energized and power flows from shore power through the NC contacts to the refrigerator. When the inverter is energized, the relay activates and the loads are connected to the inverter via the NO contacts. Shore power is isolated. This connection gives inverter priority. That is, when both shore and inverter power are available the relay selects inverter power. I wanted it that way so that if I run into bad power at a CG I can flip the inverter on to get full voltage to the microwave and reefer. I have a similar relay on the genny with genny priority. Again, I can start the genny and over-ride shore power if necessary. This gives great flexibility. For the first time ever, I ran into some bad power in Pa during my 4th vacation. In the middle of the evening the voltage was down to 100 volts. I simply fired up the genny while cooking. By the time I was through cooking the sun had set and the voltage was back up to 110, satisfactory for the AC. Whenever I wanted to nuke something, simply flip the inverter on and nuke at full voltage. John From: John De Armond Newsgroups: rec.outdoors.rv-travel Subject: Re: Thanks, for all the responses. Date: Sun, 16 Dec 2007 21:29:25 -0500 Message-ID: <7vlbm3tjea15tphpht7fb446u54e9tv26u@4ax.com> On Sun, 16 Dec 2007 17:07:30 -0700, Dapper Dave <expurgated@gmail.com> wrote: >1. How about the other side of efficiency, i.e., do some or all >appliances use more energy if being operated from a MSW source? Nothing waveform-related. Any difference will be because of the voltage difference between line and the inverter. > >2. The one appliance that does not do well with MSW power is the >microwave. It cooks at about half power when run off the inverter. A conventional microwave oven that uses a transformer/rectifier/voltage doubler (NOT the Panasonic Inverter oven and similar ones*) is heavily dependent on the peak voltage of the incoming power. The problem is that no inexpensive inverter that I've ever seen (just don't know about expensive ones) regulates the output voltage. The output voltage is roughly proportional to the input minus losses in the inverter. If say, 80 amps traveling from the battery to the inverter terminals causes a half a volt drop then that will be reflected as about a 5 volt drop in the output. That has a major effect on the microwave output. There are a couple of ways to address this. If the inverter has an internal adjustment for output voltage then cranking that up a little will help. Running the engine during microwaving also helps since that keeps the battery voltage up. The other way is a voltage booster transformer. A 12 volt transformer will add 10% (12/120). A transformer is selected with a secondary rating approximately that of the microwave input. If the microwave draws 8 amps then a 10 amp transformer is perfect. A 5 amp one will probably work since the duty cycle is short. This is a fairly small transformer. Stripping one out of an inexpensive 5 or 10 amp battery charger is a good source. The transformer is connected with its primary connected directly to the inverter output and the secondary connected in series with the hot leg feeding the microwave. Polarity matters - one way and the voltages subtract; the other way and they add. This is the approach I used in my semi truck and am using in my MH. The transformer can be mounted next to the outlet where the microwave plugs in, assuming that the inverter is connected to feed the RV's electrical system. Or a short heavy duty extension cord can be cut and the transformer wired in. The voltage boost won't hurt the microwave when operated on shore power so it can be left in place permanently. >It >draws do much current that running it from batteries doesn't make much >sense wanyway, though. Au contraire!! A 1000 watt input (6-700 watt output) microwave will consume about an amp-hour a minute. Thus, if you take 3 minutes to pop a bag of popcorn, you've only used about 3 amp-hours from the battery (not including Perkeut, of course). A 10 minute Hungry Man TV dinner uses on 10 amp-hours. That's just a drop in the bucket against a 3-400 amp-hour house battery. The key is to have the inverter-to-battery wiring the proper size to drop absolutely minimal voltage. I use 3 100 amp-hour 12 volt batteries in parallel. All the cabling is "0". The inverter is no more than a foot away from the batteries. Other than the inherent voltage drop of a heavily loaded battery, there is essentially no voltage drop even at 100 amps. One has to pay attention to connectors too. I found that a heavy eye lug attached to the steel stud on the battery post dropped a couple hundred millivolts at 100 amps while a crimped SAE post connector dropped less than 50. Same thing with a coffee-maker, for that matter. In my semi, I had a Mr Coffee-type coffee-maker. I set it up at the beginning of a sleep period, loaded with coffee and water and left it plugged into the inverter. When the Screamin' Meanie pried my eyes open :-), I swatted at the power switch until I managed to turn it on. When the Screamin' Meanie's snooze alarm finally woke me up, coffee was hot and waiting. For me a matter of survival! The whole process used not more than 5 amp-hours. I REALLY don't like to run my generator for just a few minutes at a time so most of my nuking and coffee-making and bread toasting is done on battery power when I'm off shore power. I crank the generator only when the batteries need charging. Or when I need the AC, of course. > >3. I am currently in the slow process of ordering a newer charger for my >Black & Decker drill. I wonder if the old charger failed because we >frequently operate everything from the inverter. Also, our fairly new >KitchenAid blender died last week. Maybe I'll reconsider my opinion that >everything we have is happy with our Xantrex MSW inverter. I doubt that it caused the failure. My DeWalt charger isn't damaged by the MSW power, it just doesn't do anything. It uses an ancient but very good reference design developed by Zilog back when the Z8 processor was hot spit. I know the guy who wrote the firmware so when I remember to ask, I'll find out why the thing doesn't like MSW power. The only other problem I've had, and this time the blue smoke actually leaked out, was with the Schumacher 40 amp smart charger like Wallyworld sold a few years ago. It apparently has an input power factor corrector circuit that demands low distortion input power. Mine instantly smoked when I plugged it in to the inverter. The replacement smoked when I plugged it in to one of my smaller generators. The generator waveform isn't EU-quality but it isn't THAT bad. Just a bad design on Schumacher's part. Too bad. I really liked that charger otherwise. John * I have a Panasonic inverter microwave. It kicks ass! It doesn't care about what kind of power it's fed as long as it's close to 120 volts. The microwave power is regulated. Variable power is just that, variable and not on/off like conventional microwaves. It's quite light too, since it doesn't contain that heavy transformer. From: John De Armond Newsgroups: rec.outdoors.rv-travel Subject: Re: Newbie microwave question Date: Thu, 17 Apr 2008 20:13:06 -0400 Message-ID: <vaof04pm9uegs4nu647ppanfbq3m3o8995@4ax.com> On 17 Apr 2008 18:02:01 -0500, nothermark <nothermark@not.here> wrote: >Just warming up dinner and started thinking about power consumption. >Is it reasonable to run a mh microwave off the batteries for, say, 10 >minutes. I'm thinking of pulling over and warming up two cans of soup >or whatever for lunch. I'm assuming the mh will come with a 1500 w >inverter (is this typical?) and wondering if the on board batteries >should handle the load. Sure. I run mine that way all the time. I have a nominal 600 watt oven that draws about 900 watts from the line. A 1000 or 1500 watt inverter runs mine just fine. In fact, I leave my oven connected to the inverter all the time, even on shore power. I have an 80 amp Intellipower converter that can supply almost all the current the microwave needs and will top off the batteries quickly after the cooking is done. Some things to be aware of. Microwave ovens are VERY sensitive to the peak voltage, which with nominal 120 volt shore power is about 170 volts. So-called "modified sine" inverters (actually modified square wave) output a peak voltage in the range of 140 to 150, depending on the model. This results in the microwave producing less heat, even when the batteries are in tip-top shape. Implied in that is that you have to do everything you can to maintain the voltage. Most inexpensive inverters (every one I've ever had on my bench) do not regulate the 120 volt output. It varies with the incoming 12 volt variations. That implies that losses in the 12 volt side have to be minimized. Short, very large cables and low impedance batteries. Forget wire tables. Use the largest cable that will fit and keep it as short as possible. I rearranged my battery system last year to a) move the batteries inside, b) install three Group 29 size 12 volt batteries in parallel and c) mount the inverter less than a foot away from the batteries and make the connections with 4/0 welding cable. This improved the microwave oven performance remarkably. Previously I had two Group 29 batteries mounted under the hood and connected with several feet of 4/0 cable. The combination of battery voltage sag under heavy load and the tiny voltage drop across the cables resulted in a little less output voltage and that resulted in a lot less microwave oven heat. The measured output of my oven was previously about half its rating. I haven't measured it yet with the new setup but I'm going to guesstimate that it produces between 2/3rds and 3/4ths of the rated power. I moved my batteries inside primarily to avoid the loss in capacity in cold weather (I do a lot of winter camping) but the side benefit is much improved microwave oven performance. A 2500 watt inverter will probably be necessary for your oven. Harbor Freight is currently listing one in their mail flyer for $149. It's a pretty good inverter. Two batteries in parallel will be marginal. It'll work but the heat output will be low. OK if you have patience. Three batteries should be pretty decent. The inverter will pull at least 100 amps and probably a bit more. Split three ways, about 35 amps per battery won't cause the voltage to sag too much. One more comment. I've smoked several microwave electronic control boards with less than good power in my concession stand. This happened when I overloaded my generator and the power quality deteriorated. I now avoid electronic controls whenever I can. My RV microwave and the ones in my concession stand all use mechanical timers, the kind where you turn the knob to the desired minutes. The mechanical timers are bullet-proof. I selected the oven that is in my RV on two main parameters - power draw less than 1000 watts (1kW inverters were still quite expensive back then) and the mechanical timer. I can't recall without looking but I believe that it is a low end Panasonic that cost less than $50. Substantially better quality timer than what is on the really low end Wallyworld oven that sells for about $30. John From: John De Armond Newsgroups: alt.energy.homepower,alt.engineering.electrical, sci.electronics.repair Subject: Re: uWave ovens, was: 280V motor on 230V circuit Date: Fri, 30 May 2008 03:00:23 -0400 Message-ID: <pa9v345van4btg3856m951pgkb22pqbqem@4ax.com> On Fri, 30 May 2008 01:50:29 GMT, hatespam@hatespam.com (Fiat Sparks) wrote: >Sam Goldwasser <sam@minus.seas.upenn.edu> wrote: > >>Never seen an FR uwave. :) Why would they use that when the basic >>circuit is adequate and reliable (more or less!)? > >Mostly less! :-) My Panasonic inverter unit just released the magic >smoke. First the magenetron died, and then after I replaced that, an >IGBT in the switcher shorted and did a fair bit of collateral damage. > >I finally did find a service manual...in spanish (which I read >poorly,) but it did at least tell me what all the small resistors and >diodes were supposed to be (before they melted.) > >So, $100 in parts later, I now have a working microwave again. And, if >I get tired of it, I can sell it on Craigslist for at least $35! :-/ Don't try to operate that oven from a cheap generator with a less than perfect sine output. That's another excuse for the blue smoke to leak out. BTDT. In my case I wasn't about to spend that kind of money to repair an oven that barely cost that much, especially since I used it in my restaurant always on high. Therefore I yanked out all those fancy electronics and installed the transformer/diode/cap assembly from another old oven. I drilled a hole through that nice touch pad and installed an Intermatic spring-wound timer from Home Depot. Voila, good as new and bullet-proof against nasty power. John |
|